Ooops, sorry the page you requested does not exist.

Please visit our home page.

               
Are you looking for:
SMI Stainless Steel Tubing for Flow Disc Stainless steel tubing for connecting AUX-APC to the SMI Flow Disc. Use with nut 227-35018-08 and ferrule 227-35019-01.
Rtx-1 Cap. Column 15m, 0.32mm ID, 0.10um Rtx-1 Columns Material: (fused silica) Phase Information: nonpolar phase; Crossbond dimethyl polysiloxane • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. • Long lifetime and very low bleed at high operating temperatures. • Equivalent to USP G1, G2, G38 phases. Similar Phases: HP-1, DB-1, CP-Sil 5 CB, ZB-1 DF: 0.10 µm ID: 0.32 mm Length: 15 m Product Name: Rtx-1 Product Type: GC Column Similar to: Agilent 123-1011 Similar to: Varian CP7814 Similar to: Grace 13673, 8635147 Temp Limits: -60 to 330/350 °C Units: ea.
Rtx-1 Cap. Column 30m, 0.32mm ID, 0.10um Rtx-1 Columns Material: (fused silica) Phase Information: nonpolar phase; Crossbond dimethyl polysiloxane • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. • Long lifetime and very low bleed at high operating temperatures. • Equivalent to USP G1, G2, G38 phases. Similar Phases: HP-1, DB-1, CP-Sil 5 CB, ZB-1 DF: 0.10 µm ID: 0.32 mm Length: 30 m Product Name: Rtx-1 Product Type: GC Column Similar to: Agilent 123-1031, 19091Z-313 Similar to: Varian CP7855, CP8740 Similar to: Grace 13699, 8635252 Temp Limits: -60 to 330/350 °C Units: ea.
Rtx-1 Cap. Column 30m, 0.25mm ID, 0.10um Rtx-1 Columns Material: (fused silica) Phase Information: nonpolar phase; Crossbond dimethyl polysiloxane • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. • Long lifetime and very low bleed at high operating temperatures. • Equivalent to USP G1, G2, G38 phases. Similar Phases: HP-1, DB-1, CP-Sil 5 CB, ZB-1 DF: 0.10 µm ID: 0.25 mm Length: 30 m Product Name: Rtx-1 Product Type: GC Column Similar to: Agilent 122-1031, 19091Z-333 Similar to: Phenomenex 7HG-G001-02 Similar to: Varian CP7817, CP8710 Similar to: Grace 13663, 8635233 Temp Limits: -60 to 330/350 °C Units: ea.
Rtx-1 Cap. Column 15m, 0.53mm ID, 0.10um Rtx-1 Columns Material: (fused silica) Phase Information: nonpolar phase; Crossbond dimethyl polysiloxane • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. • Long lifetime and very low bleed at high operating temperatures. • Equivalent to USP G1, G2, G38 phases. Similar Phases: HP-1, DB-1, CP-Sil 5 CB, ZB-1 DF: 0.10 µm ID: 0.53 mm Length: 15 m Product Name: Rtx-1 Product Type: GC Column Temp Limits: -60 to 320/340 °C Units: ea.